COM-Link® Category 6 UTP – Riser

COM-Link Category 6 UTP - RiserCOM-Link Category 6 UTP - Riser

Construction:

  • Conductors: 23 AWG Solid Bare Copper
  • Cable Assembly: 4 Pairs Cabled Together

Insulation: Polyethylene

Jacket: FR-PVC

Compliance:

  • ETL Verified ANSI/TIA-568-C.2 Cat 6
  • UL Subject 444 Communications Cables
  • UL Listed Type CMR
  • UL 1666 Riser Flame Test
  • NEC Article 800
  • c(UL) Type CMR
  • ICEA S-90-661
  • California State Fire Marshal
  • RoHS Compliant

Applications:

  • Gigabit Ethernet (1000Base-T)
  • Multimedia and ISDN
  • High-Speed Voice/Data Applications
  • 1.2 Gbps Ethernet
  • Broadband Video
  • Desktop Publishing

38677, 38678, 35882, 35897, 35184

Part Numbers & Available Put Ups

 Jacket ColorPart Number1,000' BoxBulk ReelsSpec 
 
 
BLUE38677XXSpec
 
 
GRAY35882XXSpec
 
 
GREEN35897XXSpec
 
 
WHITE38678XXSpec
 
YELLOW35184XXSpec

Physical Data

Nominal Cable Diameter (inches)0.205
Nominal Cable Weight (lbs./1,000 ft.)23.0
Installation Temperature Rating (Celsius)0 to +60
Operation Temperature Rating (Celsius)-20 to +75
Pulling Force (Max lbs.)32.0

Transmission Throughput

Char. Impedance Freq. (MHz)Char. Impedance (Ohms) (+/-15)Return Loss (dB) (Min.)Attenuation dB / 100m (Max.)NEXT dB / 100m (Min.)PSNEXT dB / 100m (Min.)ACRF dB / 100m (Min.)PSACRF dB / 100m (Min.)
110020274.372.367.864.8
4100233.865.363.355.752.7
810024.55.360.858.849.746.7
1010025659.357.347.844.8
16100257.656.354.343.740.7
20100258.554.852.841.738.7
2510024.39.553.351.339.836.8
31.2510023.610.751.949.937.934.9
62.510021.515.447.445.431.828.8
10010020.119.844.342.327.824.8
12510019.422.442.940.925.822.8
155.5210018.825.241.439.423.920.9
17510018.426.940.738.722.919.9
200100182939.837.821.718.7
25010017.332.838.336.319.816.8