COM-Link® COM-Pact Category 6e – Plenum

COM-Link COM-Pact Category 6e - PlenumCOM-Link COM-Pact Category 6e - Plenum
Construction:

  • Conductors: 23 AWG Solid Bare Copper
  • Cable Assembly: 4 Pairs Cabled Together

Insulation: Fluoropolymer

Jacket: Plenum PVC

Compliance:

  • UL Subject 444 Communications Cables
  • UL Listed Type CMP
  • NFPA 262, UL 910
  • NEC Article 800
  • c(UL) Type CMP
  • ICEA S-102-700
  • California State Fire Marshal
  • RoHS Compliant

Applications:

  • Gigabit Ethernet (1000Base-T)
  • Multimedia and ISDN
  • High-Speed Voice/Data Applications
  • 1.2 Gbps Ethernet
  • Broadband Video
  • Desktop Publishing

36046, 36047

 

Part Numbers & Available Put Ups

 Jacket ColorPart Number1,000' Box1,000' ReelsBulk ReelsSpec 
 
 
BLUE36046XXXSpec
 
 
WHITE36047XXXSpec

Physical Data

Nominal Cable Diameter (inches)0.198
Nominal Cable Weight (lbs./1,000 ft.)23.0
Installation Temperature Rating (Celsius)0 to +60
Operation Temperature Rating (Celsius)-20 to +75
Pulling Force (Max lbs.)32

Transmission Throughput

Char. Impedance Freq. (MHz)Char. Impedance (Ohms) (+/-15)Return Loss (dB) (Min.)Attenuation dB / 100m (Max.)NEXT dB / 100m (Min.)PSNEXT dB / 100m (Min.)ACRF dB / 100m (Min.)PSACRF dB / 100m (Min.)
110020274.372.367.864.8
4100233.865.363.355.852.8
810024.55.360.858.849.746.7
1010025659.357.347.844.8
16100257.656.254.243.740.7
20100258.554.852.841.838.8
2510024.39.553.351.339.836.8
31.2510023.610.751.949.937.934.9
62.510021.515.447.445.431.928.9
10010020.119.844.342.327.824.8
12510019.422.442.940.925.822.8
15510018.825.241.439.423.920.9
17510018.426.940.738.722.919.9
200100182939.837.821.818.8
25010017.332.838.336.319.816.8
30010016.836.437.135.118.315.3
35010016.339.836.134.116.913.9
40010015.94335.333.315.812.8
45010015.54634.532.514.711.7
50010015.248.933.831.813.810.8
55010014.951.833.231.21310