VITALink® 2 Hour Fire Resistive CIC/CI (Shielded)

VITALink® is a registered trademark of RSCC Wire & Cable, LLC, a Marmon Wire & Cable/Berkshire Hathaway Company.

VITALink® 2 Hour Fire Resistive CIC

Construction:

  • Conductors: 14 – 18 AWG Solid Cu. specially engineered to minimize embrittlement due to fire exposure
  • Tape (Not P/N 35787): Flame Retardant Tape
  • Core Assembly: Color coded conductors: Black and Red
  • Shield: Copper/Polyester Tape applied over core
  • Drain Wire: Stranded Bare Copper

Insulation: Low Smoke, Zero Halogen Thermoset Fire-Roc™

Jacket: Red Low Smoke, Zero Halogen Polyolefin (sequential footage marker provided every 2 feet)

Applications: 

  • Emergency Voice/Alarm Communication Smoke and Fire Alarm Systems
  • Fireman’s Telephone and Area of Refuge Communication Systems
  • Visible Notification Appliances

 


Part Numbers & Specs

SpecPart NumberNo. of ConductorsAWGNominal Diameter (inches)Nominal Weight (lbs./1000 ft.)Nominal Capacitance (pF/ft.) 
Spec35787214.3427636
Spec36316214.3536425
Spec35785216.3306020
Spec36397218.3094917

P/N 35787

Notes:

  • Refer to Spec above for hardware certifications
  • Refer to UL Electrical Circuit Integrity System FHIT.40 for installation requirements
  • Refer to FHJR.R27557 Fire Resistive Cable
  • VITALink® Brand Type cables for use in System No. FHIT.40 when installed in accordance with the manufacturer’s installation instructions dated May 2014
  • Authorities having Jurisdiction should be consulted before installation

Compliance:

  • NEC Type FPLR, CMR, & CL3R for use in Electrical Circuit Integrity System FHIT 40
  • UL Certified to ANSI/UL 2196 2 Hour Fire Rating for use in FHIT system 40 (See UL Fire Resistance Directory R27557)
  • UL 1424 Listed FPLR for Power-Limited Fire Alarm Circuits, 300V / 90°C
  • UL 13 Listed CL3R for Power-Limited Circuit Cables; 300V / 90°C
  • UL 444 Listed CMR for Communication Cable; 300V / 90°C
  • Fire certified for power-limited system use at 50V phase-to-phase utilization voltage

P/Ns 36316, 35785, and 36397

Notes:

  • Refer to Specs above for hardware certifications
  • Refer to R27557 Fire Resistive Cable (UL)
  • VITALink® Brand Type FPLR-CI-LS, CMR-CI-LS, & PLTC-CI-LS for use in System No. FHT.40A and FHIT7.40A when installed in accordance with the manufacturer’s installation instructions dated May 2017 for use as CIC cable
  • For use as CI cable when installed per the NEC and local code. For vertical installation lengths beyond 30 ft. (18 AWG) or 45 ft. (16 & 14 AWG) cables are to be supported using a stainless steel wire mesh.
  • Authorities having Jurisdiction should be consulted before installation

Compliance:

  • NEC type FPLR-CI-LS, CMR-CI-LS, & PLTC-CI-LS for use in Electrical Circuit Integrity System FHIT 40A
  • c(UL) Listed CMR-LS
  • CEC and CSA Listed FAS90 to C22.2 No. 208-14
  • UL Certified to ANSI/UL 2196 2-Hour fire rating for use in FHIT system 40A. (See UL Fire Resistance Directory R27557)
  • CAN/ULC-S139 Certified with Hose Stream Test for use in FHIT7 system 40A
  • UL 1424 Listed FPLR-CI-LS for Power-Limited Fire Alarm Cables; 300V / 105°C
  • UL 13 Listed PLTC-CI-LS for Power-Limited Circuit Cables; 300V / 105°C
  • UL 444 Listed CMR-CI-LS for Communication Cable; 300V / 105°C
  • Fire certified for power-limited system use at 72V phase-to-phase utilization voltage
  • Sunlight Resistant
  • For use in wet locations
  • NYC Electrical Advisory Board approval # 54502, April 2017
  • California State Fire Marshal Approved